]> git.mxchange.org Git - friendica.git/blobdiff - include/poller.php
proc_run was replaced
[friendica.git] / include / poller.php
index b08d98ca75b225fc46eb66ffd97c7159d81fa9e1..6eb04971c39844e4dacfac370b75da374653a397 100644 (file)
@@ -1,10 +1,9 @@
 <?php
-
 use Friendica\App;
+use Friendica\Core\Worker;
 use Friendica\Core\Config;
-use Friendica\Util\Lock;
 
-if (!file_exists("boot.php") AND (sizeof($_SERVER["argv"]) != 0)) {
+if (!file_exists("boot.php") && (sizeof($_SERVER["argv"]) != 0)) {
        $directory = dirname($_SERVER["argv"][0]);
 
        if (substr($directory, 0, 1) != "/") {
@@ -17,18 +16,23 @@ if (!file_exists("boot.php") AND (sizeof($_SERVER["argv"]) != 0)) {
 
 require_once("boot.php");
 
-function poller_run($argv, $argc){
-       global $a, $db;
+function poller_run($argv, $argc) {
+       global $a;
 
-       $a = new App(dirname(__DIR__));
+       if (empty($a)) {
+               $a = new App(dirname(__DIR__));
+       }
 
-       @include(".htconfig.php");
-       require_once("include/dba.php");
-       $db = new dba($db_host, $db_user, $db_pass, $db_data);
+       require_once ".htconfig.php";
+       require_once "include/dba.php";
+       dba::connect($db_host, $db_user, $db_pass, $db_data);
        unset($db_host, $db_user, $db_pass, $db_data);
 
        Config::load();
 
+       // Check the database structure and possibly fixes it
+       check_db(true);
+
        // Quit when in maintenance
        if (Config::get('system', 'maintenance', true)) {
                return;
@@ -47,710 +51,18 @@ function poller_run($argv, $argc){
        // We now start the process. This is done after the load check since this could increase the load.
        $a->start_process();
 
-       // At first we check the number of workers and quit if there are too much of them
-       // This is done at the top to avoid that too much code is executed without a need to do so,
-       // since the poller mostly quits here.
-       if (poller_too_much_workers()) {
-               poller_kill_stale_workers();
-               logger('Pre check: Active worker limit reached, quitting.', LOGGER_DEBUG);
-               return;
-       }
-
-       // Do we have too few memory?
-       if ($a->min_memory_reached()) {
-               logger('Pre check: Memory limit reached, quitting.', LOGGER_DEBUG);
-               return;
-       }
-
-       // Possibly there are too much database connections
-       if (poller_max_connections_reached()) {
-               logger('Pre check: maximum connections reached, quitting.', LOGGER_DEBUG);
-               return;
-       }
-
-       // Possibly there are too much database processes that block the system
-       if ($a->max_processes_reached()) {
-               logger('Pre check: maximum processes reached, quitting.', LOGGER_DEBUG);
-               return;
-       }
-
-       // Now we start additional cron processes if we should do so
-       if (($argc <= 1) OR ($argv[1] != "no_cron")) {
-               poller_run_cron();
-       }
-
-       $starttime = time();
-
-       // We fetch the next queue entry that is about to be executed
-       while ($r = poller_worker_process()) {
-
-               // If we got that queue entry we claim it for us
-               if (!poller_claim_process($r[0])) {
-                       continue;
-               }
-
-               // To avoid the quitting of multiple pollers only one poller at a time will execute the check
-               if (Lock::set('poller_worker', 0)) {
-                       // Count active workers and compare them with a maximum value that depends on the load
-                       if (poller_too_much_workers()) {
-                               logger('Active worker limit reached, quitting.', LOGGER_DEBUG);
-                               return;
-                       }
-
-                       // Check free memory
-                       if ($a->min_memory_reached()) {
-                               logger('Memory limit reached, quitting.', LOGGER_DEBUG);
-                               return;
-                       }
-                       Lock::remove('poller_worker');
-               }
-
-               // finally the work will be done
-               if (!poller_execute($r[0])) {
-                       logger('Process execution failed, quitting.', LOGGER_DEBUG);
-                       return;
-               }
-
-               // Quit the poller once every hour
-               if (time() > ($starttime + 3600)) {
-                       logger('Process lifetime reached, quitting.', LOGGER_DEBUG);
-                       return;
-               }
-       }
-       logger("Couldn't select a workerqueue entry, quitting.", LOGGER_DEBUG);
-}
-
-/**
- * @brief Execute a worker entry
- *
- * @param array $queue Workerqueue entry
- *
- * @return boolean "true" if further processing should be stopped
- */
-function poller_execute($queue) {
-
-       $a = get_app();
-
-       $mypid = getmypid();
-
-       // Quit when in maintenance
-       if (Config::get('system', 'maintenance', true)) {
-               logger("Maintenance mode - quit process ".$mypid, LOGGER_DEBUG);
-               return false;
-       }
-
-       // Constantly check the number of parallel database processes
-       if ($a->max_processes_reached()) {
-               logger("Max processes reached for process ".$mypid, LOGGER_DEBUG);
-               return false;
-       }
-
-       // Constantly check the number of available database connections to let the frontend be accessible at any time
-       if (poller_max_connections_reached()) {
-               logger("Max connection reached for process ".$mypid, LOGGER_DEBUG);
-               return false;
-       }
-
-       $argv = json_decode($queue["parameter"]);
-
-       // Check for existance and validity of the include file
-       $include = $argv[0];
-
-       if (!validate_include($include)) {
-               logger("Include file ".$argv[0]." is not valid!");
-               dba::delete('workerqueue', array('id' => $queue["id"]));
-               return true;
-       }
-
-       require_once($include);
-
-       $funcname = str_replace(".php", "", basename($argv[0]))."_run";
-
-       if (function_exists($funcname)) {
-               poller_exec_function($queue, $funcname, $argv);
-               dba::delete('workerqueue', array('id' => $queue["id"]));
-       } else {
-               logger("Function ".$funcname." does not exist");
-       }
-
-       return true;
-}
-
-/**
- * @brief Execute a function from the queue
- *
- * @param array $queue Workerqueue entry
- * @param string $funcname name of the function
- * @param array $argv Array of values to be passed to the function
- */
-function poller_exec_function($queue, $funcname, $argv) {
-
-       $a = get_app();
-
-       $mypid = getmypid();
-
-       $argc = count($argv);
-
-       logger("Process ".$mypid." - Prio ".$queue["priority"]." - ID ".$queue["id"].": ".$funcname." ".$queue["parameter"]);
-
-       $stamp = (float)microtime(true);
-
-       // We use the callstack here to analyze the performance of executed worker entries.
-       // For this reason the variables have to be initialized.
-       if (Config::get("system", "profiler")) {
-               $a->performance["start"] = microtime(true);
-               $a->performance["database"] = 0;
-               $a->performance["database_write"] = 0;
-               $a->performance["network"] = 0;
-               $a->performance["file"] = 0;
-               $a->performance["rendering"] = 0;
-               $a->performance["parser"] = 0;
-               $a->performance["marktime"] = 0;
-               $a->performance["markstart"] = microtime(true);
-               $a->callstack = array();
-       }
-
-       // For better logging create a new process id for every worker call
-       // But preserve the old one for the worker
-       $old_process_id = $a->process_id;
-       $a->process_id = uniqid("wrk", true);
-
-       $funcname($argv, $argc);
-
-       $a->process_id = $old_process_id;
-
-       $duration = number_format(microtime(true) - $stamp, 3);
-
-       if ($duration > 3600) {
-               logger("Prio ".$queue["priority"].": ".$queue["parameter"]." - longer than 1 hour (".round($duration/60, 3).")", LOGGER_DEBUG);
-       } elseif ($duration > 600) {
-               logger("Prio ".$queue["priority"].": ".$queue["parameter"]." - longer than 10 minutes (".round($duration/60, 3).")", LOGGER_DEBUG);
-       } elseif ($duration > 300) {
-               logger("Prio ".$queue["priority"].": ".$queue["parameter"]." - longer than 5 minutes (".round($duration/60, 3).")", LOGGER_DEBUG);
-       } elseif ($duration > 120) {
-               logger("Prio ".$queue["priority"].": ".$queue["parameter"]." - longer than 2 minutes (".round($duration/60, 3).")", LOGGER_DEBUG);
-       }
-
-       logger("Process ".$mypid." - Prio ".$queue["priority"]." - ID ".$queue["id"].": ".$funcname." - done in ".$duration." seconds.");
-
-       // Write down the performance values into the log
-       if (Config::get("system", "profiler")) {
-               $duration = microtime(true)-$a->performance["start"];
-
-               if (Config::get("rendertime", "callstack")) {
-                       if (isset($a->callstack["database"])) {
-                               $o = "\nDatabase Read:\n";
-                               foreach ($a->callstack["database"] AS $func => $time) {
-                                       $time = round($time, 3);
-                                       if ($time > 0) {
-                                               $o .= $func.": ".$time."\n";
-                                       }
-                               }
-                       }
-                       if (isset($a->callstack["database_write"])) {
-                               $o .= "\nDatabase Write:\n";
-                               foreach ($a->callstack["database_write"] AS $func => $time) {
-                                       $time = round($time, 3);
-                                       if ($time > 0) {
-                                               $o .= $func.": ".$time."\n";
-                                       }
-                               }
-                       }
-                       if (isset($a->callstack["network"])) {
-                               $o .= "\nNetwork:\n";
-                               foreach ($a->callstack["network"] AS $func => $time) {
-                                       $time = round($time, 3);
-                                       if ($time > 0) {
-                                               $o .= $func.": ".$time."\n";
-                                       }
-                               }
-                       }
-               } else {
-                       $o = '';
-               }
-
-               logger("ID ".$queue["id"].": ".$funcname.": ".sprintf("DB: %s/%s, Net: %s, I/O: %s, Other: %s, Total: %s".$o,
-                       number_format($a->performance["database"] - $a->performance["database_write"], 2),
-                       number_format($a->performance["database_write"], 2),
-                       number_format($a->performance["network"], 2),
-                       number_format($a->performance["file"], 2),
-                       number_format($duration - ($a->performance["database"] + $a->performance["network"] + $a->performance["file"]), 2),
-                       number_format($duration, 2)),
-                       LOGGER_DEBUG);
-       }
-
-       $cooldown = Config::get("system", "worker_cooldown", 0);
-
-       if ($cooldown > 0) {
-               logger("Process ".$mypid." - Prio ".$queue["priority"]." - ID ".$queue["id"].": ".$funcname." - in cooldown for ".$cooldown." seconds");
-               sleep($cooldown);
-       }
-}
-
-/**
- * @brief Checks if the number of database connections has reached a critical limit.
- *
- * @return bool Are more than 3/4 of the maximum connections used?
- */
-function poller_max_connections_reached() {
-
-       // Fetch the max value from the config. This is needed when the system cannot detect the correct value by itself.
-       $max = Config::get("system", "max_connections");
-
-       // Fetch the percentage level where the poller will get active
-       $maxlevel = Config::get("system", "max_connections_level", 75);
-
-       if ($max == 0) {
-               // the maximum number of possible user connections can be a system variable
-               $r = q("SHOW VARIABLES WHERE `variable_name` = 'max_user_connections'");
-               if (dbm::is_result($r)) {
-                       $max = $r[0]["Value"];
-               }
-               // Or it can be granted. This overrides the system variable
-               $r = q("SHOW GRANTS");
-               if (dbm::is_result($r)) {
-                       foreach ($r AS $grants) {
-                               $grant = array_pop($grants);
-                               if (stristr($grant, "GRANT USAGE ON")) {
-                                       if (preg_match("/WITH MAX_USER_CONNECTIONS (\d*)/", $grant, $match)) {
-                                               $max = $match[1];
-                                       }
-                               }
-                       }
-               }
-       }
-
-       // If $max is set we will use the processlist to determine the current number of connections
-       // The processlist only shows entries of the current user
-       if ($max != 0) {
-               $r = q("SHOW PROCESSLIST");
-               if (!dbm::is_result($r)) {
-                       return false;
-               }
-               $used = count($r);
-
-               logger("Connection usage (user values): ".$used."/".$max, LOGGER_DEBUG);
-
-               $level = ($used / $max) * 100;
-
-               if ($level >= $maxlevel) {
-                       logger("Maximum level (".$maxlevel."%) of user connections reached: ".$used."/".$max);
-                       return true;
-               }
-       }
-
-       // We will now check for the system values.
-       // This limit could be reached although the user limits are fine.
-       $r = q("SHOW VARIABLES WHERE `variable_name` = 'max_connections'");
-       if (!dbm::is_result($r)) {
-               return false;
-       }
-       $max = intval($r[0]["Value"]);
-       if ($max == 0) {
-               return false;
-       }
-       $r = q("SHOW STATUS WHERE `variable_name` = 'Threads_connected'");
-       if (!dbm::is_result($r)) {
-               return false;
-       }
-       $used = intval($r[0]["Value"]);
-       if ($used == 0) {
-               return false;
-       }
-       logger("Connection usage (system values): ".$used."/".$max, LOGGER_DEBUG);
-
-       $level = $used / $max * 100;
-
-       if ($level < $maxlevel) {
-               return false;
-       }
-       logger("Maximum level (".$level."%) of system connections reached: ".$used."/".$max);
-       return true;
-}
-
-/**
- * @brief fix the queue entry if the worker process died
- *
- */
-function poller_kill_stale_workers() {
-       $r = q("SELECT `pid`, `executed`, `priority`, `parameter` FROM `workerqueue` WHERE `executed` > '%s'", dbesc(NULL_DATE));
-
-       if (!dbm::is_result($r)) {
-               // No processing here needed
-               return;
-       }
-
-       foreach ($r AS $pid) {
-               if (!posix_kill($pid["pid"], 0)) {
-                       dba::update('workerqueue', array('executed' => NULL_DATE, 'pid' => 0),
-                                       array('pid' => $pid["pid"]));
-               } else {
-                       // Kill long running processes
+       $run_cron = (($argc <= 1) || ($argv[1] != "no_cron"));
 
-                       // Check if the priority is in a valid range
-                       if (!in_array($pid["priority"], array(PRIORITY_CRITICAL, PRIORITY_HIGH, PRIORITY_MEDIUM, PRIORITY_LOW, PRIORITY_NEGLIGIBLE))) {
-                               $pid["priority"] = PRIORITY_MEDIUM;
-                       }
-                       // Define the maximum durations
-                       $max_duration_defaults = array(PRIORITY_CRITICAL => 360, PRIORITY_HIGH => 10, PRIORITY_MEDIUM => 60, PRIORITY_LOW => 180, PRIORITY_NEGLIGIBLE => 360);
-                       $max_duration = $max_duration_defaults[$pid["priority"]];
-
-                       $argv = json_decode($pid["parameter"]);
-                       $argv[0] = basename($argv[0]);
-
-                       // How long is the process already running?
-                       $duration = (time() - strtotime($pid["executed"])) / 60;
-                       if ($duration > $max_duration) {
-                               logger("Worker process ".$pid["pid"]." (".implode(" ", $argv).") took more than ".$max_duration." minutes. It will be killed now.");
-                               posix_kill($pid["pid"], SIGTERM);
-
-                               // We killed the stale process.
-                               // To avoid a blocking situation we reschedule the process at the beginning of the queue.
-                               // Additionally we are lowering the priority.
-                               dba::update('workerqueue',
-                                               array('executed' => NULL_DATE, 'created' => datetime_convert(), 'priority' => PRIORITY_NEGLIGIBLE, 'pid' => 0),
-                                               array('pid' => $pid["pid"]));
-                       } else {
-                               logger("Worker process ".$pid["pid"]." (".implode(" ", $argv).") now runs for ".round($duration)." of ".$max_duration." allowed minutes. That's okay.", LOGGER_DEBUG);
-                       }
-               }
-       }
-}
-
-/**
- * @brief Checks if the number of active workers exceeds the given limits
- *
- * @return bool Are there too much workers running?
- */
-function poller_too_much_workers() {
-       $queues = Config::get("system", "worker_queues", 4);
-
-       $maxqueues = $queues;
-
-       $active = poller_active_workers();
-
-       // Decrease the number of workers at higher load
-       $load = current_load();
-       if ($load) {
-               $maxsysload = intval(Config::get("system", "maxloadavg", 50));
-
-               $maxworkers = $queues;
-
-               // Some magical mathemathics to reduce the workers
-               $exponent = 3;
-               $slope = $maxworkers / pow($maxsysload, $exponent);
-               $queues = ceil($slope * pow(max(0, $maxsysload - $load), $exponent));
-
-               // Create a list of queue entries grouped by their priority
-               $listitem = array();
-
-               // Adding all processes with no workerqueue entry
-               $processes = dba::p("SELECT COUNT(*) AS `running` FROM `process` WHERE NOT EXISTS (SELECT id FROM `workerqueue` WHERE `workerqueue`.`pid` = `process`.`pid`)");
-               if ($process = dba::fetch($processes)) {
-                       $listitem[0] = "0:".$process["running"];
-               }
-               dba::close($processes);
-
-               // Now adding all processes with workerqueue entries
-               $entries = dba::p("SELECT COUNT(*) AS `entries`, `priority` FROM `workerqueue` GROUP BY `priority`");
-               while ($entry = dba::fetch($entries)) {
-                       $processes = dba::p("SELECT COUNT(*) AS `running` FROM `process` INNER JOIN `workerqueue` ON `workerqueue`.`pid` = `process`.`pid` WHERE `priority` = ?", $entry["priority"]);
-                       if ($process = dba::fetch($processes)) {
-                               $listitem[$entry["priority"]] = $entry["priority"].":".$process["running"]."/".$entry["entries"];
-                       }
-                       dba::close($processes);
-               }
-               dba::close($entries);
-               $processlist = ' ('.implode(', ', $listitem).')';
-
-               $s = q("SELECT COUNT(*) AS `total` FROM `workerqueue` WHERE `executed` <= '%s'", dbesc(NULL_DATE));
-               $entries = $s[0]["total"];
-
-               if (Config::get("system", "worker_fastlane", false) AND ($queues > 0) AND ($entries > 0) AND ($active >= $queues)) {
-                       $s = q("SELECT `priority` FROM `workerqueue` WHERE `executed` <= '%s' ORDER BY `priority` LIMIT 1", dbesc(NULL_DATE));
-                       $top_priority = $s[0]["priority"];
-
-                       $s = q("SELECT `id` FROM `workerqueue` WHERE `priority` <= %d AND `executed` > '%s' LIMIT 1",
-                               intval($top_priority), dbesc(NULL_DATE));
-                       $high_running = dbm::is_result($s);
-
-                       if (!$high_running AND ($top_priority > PRIORITY_UNDEFINED) AND ($top_priority < PRIORITY_NEGLIGIBLE)) {
-                               logger("There are jobs with priority ".$top_priority." waiting but none is executed. Open a fastlane.", LOGGER_DEBUG);
-                               $queues = $active + 1;
-                       }
-               }
-
-               logger("Load: ".$load."/".$maxsysload." - processes: ".$active."/".$entries.$processlist." - maximum: ".$queues."/".$maxqueues, LOGGER_DEBUG);
-
-               // Are there fewer workers running as possible? Then fork a new one.
-               if (!Config::get("system", "worker_dont_fork") AND ($queues > ($active + 1)) AND ($entries > 1)) {
-                       logger("Active workers: ".$active."/".$queues." Fork a new worker.", LOGGER_DEBUG);
-                       $args = array("include/poller.php", "no_cron");
-                       $a = get_app();
-                       $a->proc_run($args);
-               }
-       }
-
-       return $active >= $queues;
+       Worker::processQueue($run_cron);
+       return;
 }
 
-/**
- * @brief Returns the number of active poller processes
- *
- * @return integer Number of active poller processes
- */
-function poller_active_workers() {
-       $workers = q("SELECT COUNT(*) AS `processes` FROM `process` WHERE `command` = 'poller.php'");
-
-       return $workers[0]["processes"];
-}
+if (array_search(__file__, get_included_files()) === 0) {
+       poller_run($_SERVER["argv"], $_SERVER["argc"]);
 
-/**
- * @brief Check if we should pass some slow processes
- *
- * When the active processes of the highest priority are using more than 2/3
- * of all processes, we let pass slower processes.
- *
- * @param string $highest_priority Returns the currently highest priority
- * @return bool We let pass a slower process than $highest_priority
- */
-function poller_passing_slow(&$highest_priority) {
-
-       $highest_priority = 0;
-
-       $r = q("SELECT `priority`
-               FROM `process`
-               INNER JOIN `workerqueue` ON `workerqueue`.`pid` = `process`.`pid`");
-
-       // No active processes at all? Fine
-       if (!dbm::is_result($r)) {
-               return false;
-       }
-       $priorities = array();
-       foreach ($r AS $line) {
-               $priorities[] = $line["priority"];
-       }
-       // Should not happen
-       if (count($priorities) == 0) {
-               return false;
-       }
-       $highest_priority = min($priorities);
-
-       // The highest process is already the slowest one?
-       // Then we quit
-       if ($highest_priority == PRIORITY_NEGLIGIBLE) {
-               return false;
-       }
-       $high = 0;
-       foreach ($priorities AS $priority) {
-               if ($priority == $highest_priority) {
-                       ++$high;
-               }
-       }
-       logger("Highest priority: ".$highest_priority." Total processes: ".count($priorities)." Count high priority processes: ".$high, LOGGER_DEBUG);
-       $passing_slow = (($high/count($priorities)) > (2/3));
-
-       if ($passing_slow) {
-               logger("Passing slower processes than priority ".$highest_priority, LOGGER_DEBUG);
-       }
-       return $passing_slow;
-}
-
-/**
- * @brief Returns the next worker process
- *
- * @return string SQL statement
- */
-function poller_worker_process() {
-
-       // Check if we should pass some low priority process
-       $highest_priority = 0;
-
-       if (poller_passing_slow($highest_priority)) {
-               dba::lock('workerqueue');
-
-               // Are there waiting processes with a higher priority than the currently highest?
-               $r = q("SELECT * FROM `workerqueue`
-                               WHERE `executed` <= '%s' AND `priority` < %d
-                               ORDER BY `priority`, `created` LIMIT 1",
-                               dbesc(NULL_DATE),
-                               intval($highest_priority));
-               if (dbm::is_result($r)) {
-                       return $r;
-               }
-               // Give slower processes some processing time
-               $r = q("SELECT * FROM `workerqueue`
-                               WHERE `executed` <= '%s' AND `priority` > %d
-                               ORDER BY `priority`, `created` LIMIT 1",
-                               dbesc(NULL_DATE),
-                               intval($highest_priority));
-
-               if (dbm::is_result($r)) {
-                       return $r;
-               }
-       } else {
-               dba::lock('workerqueue');
-       }
-
-       // If there is no result (or we shouldn't pass lower processes) we check without priority limit
-       if (!dbm::is_result($r)) {
-               $r = q("SELECT * FROM `workerqueue` WHERE `executed` <= '%s' ORDER BY `priority`, `created` LIMIT 1", dbesc(NULL_DATE));
-       }
-
-       // We only unlock the tables here, when we got no data
-       if (!dbm::is_result($r)) {
-               dba::unlock();
-       }
-
-       return $r;
-}
-
-/**
- * @brief Assigns a workerqueue entry to the current process
- *
- * When we are sure that the table locks are working correctly, we can remove the checks from here
- *
- * @param array $queue Workerqueue entry
- *
- * @return boolean "true" if the claiming was successful
- */
-function poller_claim_process($queue) {
-       $mypid = getmypid();
-
-       $success = dba::update('workerqueue', array('executed' => datetime_convert(), 'pid' => $mypid),
-                       array('id' => $queue["id"], 'pid' => 0));
-       dba::unlock();
-
-       if (!$success) {
-               logger("Couldn't update queue entry ".$queue["id"]." - skip this execution", LOGGER_DEBUG);
-               return false;
-       }
-
-       // Assure that there are no tasks executed twice
-       $id = q("SELECT `pid`, `executed` FROM `workerqueue` WHERE `id` = %d", intval($queue["id"]));
-       if (!$id) {
-               logger("Queue item ".$queue["id"]." vanished - skip this execution", LOGGER_DEBUG);
-               return false;
-       } elseif ((strtotime($id[0]["executed"]) <= 0) OR ($id[0]["pid"] == 0)) {
-               logger("Entry for queue item ".$queue["id"]." wasn't stored - skip this execution", LOGGER_DEBUG);
-               return false;
-       } elseif ($id[0]["pid"] != $mypid) {
-               logger("Queue item ".$queue["id"]." is to be executed by process ".$id[0]["pid"]." and not by me (".$mypid.") - skip this execution", LOGGER_DEBUG);
-               return false;
-       }
-       return true;
-}
-
-/**
- * @brief Removes a workerqueue entry from the current process
- */
-function poller_unclaim_process() {
-       $mypid = getmypid();
-
-       dba::update('workerqueue', array('executed' => NULL_DATE, 'pid' => 0), array('pid' => $mypid));
-}
-
-/**
- * @brief Call the front end worker
- */
-function call_worker() {
-       if (!Config::get("system", "frontend_worker")) {
-               return;
-       }
-
-       $url = App::get_baseurl()."/worker";
-       fetch_url($url, false, $redirects, 1);
-}
-
-/**
- * @brief Call the front end worker if there aren't any active
- */
-function call_worker_if_idle() {
-       if (!Config::get("system", "frontend_worker")) {
-               return;
-       }
-
-       // Do we have "proc_open"? Then we can fork the poller
-       if (function_exists("proc_open")) {
-               // When was the last time that we called the worker?
-               // Less than one minute? Then we quit
-               if ((time() - Config::get("system", "worker_started")) < 60) {
-                       return;
-               }
-
-               set_config("system", "worker_started", time());
-
-               // Do we have enough running workers? Then we quit here.
-               if (poller_too_much_workers()) {
-                       // Cleaning dead processes
-                       poller_kill_stale_workers();
-                       get_app()->remove_inactive_processes();
-
-                       return;
-               }
-
-               poller_run_cron();
-
-               logger('Call poller', LOGGER_DEBUG);
-
-               $args = array("include/poller.php", "no_cron");
-               $a = get_app();
-               $a->proc_run($args);
-               return;
-       }
-
-       // We cannot execute background processes.
-       // We now run the processes from the frontend.
-       // This won't work with long running processes.
-       poller_run_cron();
-
-       clear_worker_processes();
-
-       $workers = q("SELECT COUNT(*) AS `processes` FROM `process` WHERE `command` = 'worker.php'");
-
-       if ($workers[0]["processes"] == 0) {
-               call_worker();
-       }
-}
-
-/**
- * @brief Removes long running worker processes
- */
-function clear_worker_processes() {
-       $timeout = Config::get("system", "frontend_worker_timeout", 10);
-
-       /// @todo We should clean up the corresponding workerqueue entries as well
-       q("DELETE FROM `process` WHERE `created` < '%s' AND `command` = 'worker.php'",
-               dbesc(datetime_convert('UTC','UTC',"now - ".$timeout." minutes")));
-}
-
-/**
- * @brief Runs the cron processes
- */
-function poller_run_cron() {
-       logger('Add cron entries', LOGGER_DEBUG);
-
-       // Check for spooled items
-       proc_run(PRIORITY_HIGH, "include/spool_post.php");
-
-       // Run the cron job that calls all other jobs
-       proc_run(PRIORITY_MEDIUM, "include/cron.php");
-
-       // Run the cronhooks job separately from cron for being able to use a different timing
-       proc_run(PRIORITY_MEDIUM, "include/cronhooks.php");
-
-       // Cleaning dead processes
-       poller_kill_stale_workers();
-}
-
-if (array_search(__file__,get_included_files())===0){
-       poller_run($_SERVER["argv"],$_SERVER["argc"]);
-
-       poller_unclaim_process();
+       Worker::unclaimProcess();
 
        get_app()->end_process();
 
-       Lock::remove('poller_worker');
-
        killme();
 }